-6.6kV 1300kW AC Inverter Duty Motor for Mill Drives “Wannan”
-6.6kV 630kW AC Inverter Duty Motor for Presure Feeder Drives “Wannan”
-6.6 kV 2,000 kVA, Inverter Drive for Mill Motor “STEP” 36-Pulses
-6.6 kV 1,000 kVA, Inverter Drive for Mill Motor “STEP” 36-Pulses
-6.6KV Incoming Feeder Protection Panel for Main Inverter “API”
-Installation Work for Panel, Power Cable and Control Cable “API”
-3.3kV Incoming Panel (For Double VCB) : 1 Panel
-3.3kV Feeder Double VCB Panel : 6 Panel
-Protection Relay Setting for Co-Ordination Curve
-Test & Commissioning at Site
-As-Built Drawing
-Modification Busbar and Re-Connecting at Site
-SCADA System for Diffusor Process (To Monitor & Control)
-SCADA System for Refinery Process (To Monitor & Control)
-PLC & SCADAs Programming
-Site Training
-6.6 kV 800 kVA, Inverter Drive for Pump Motor “STEP” 36-Pulses
-Redundant Starter System between Existing Soft-Starter and MVD
-6.6kV MVD Feed Line Panel
-6.6kV MVD Outgoing with Bypass Control Panel
-Protection Relay Setting for Co-Ordination Curve
-PLC Programming for Starting Sequence
-Test & Commissioning at Site
-As-Built Drawing
-400V MDB Panel for Tr. 4000kVA : 1 Set
-400V MCC Panel for Ethernol Process : 4 Panel
-Installation Work for Panel, Power Cable, Control Cable and Cable Ladder “API”
-Lighting and Grounding System
-Protection Relay Setting for Co-Ordination Curve
-Test & Commissioning at Site
-As-Built Drawing
-3.3kV 750kW AC Motor for Pump 8-Pole, IC611, Anti-friction bearing “Wannan”
-3.3kV Reactor Starter Panel
-Protection Relay Setting for Co-Ordination Curve
-Test & Commissioning at Site
-As-Built Drawing
-6.6kV Main Busconnecting Panel : 2 Panel
-6.6kV Feeder Panel : 10 Panel
-6.6kV Stator Starter Panel for BFWP Motor 900kW No.1 : 2 Panel
-6.6kV Stator Starter Panel for BFWP Motor 900kW No.2 : 2 Panel
-Protection Relay Setting for Co-Ordination Curve
-Test & Commissioning at Site
-As-Built Drawing
-Batch Centrifugal Machine ” GZSM ” ( XJZ1600-N ) : 2 Sets
-400V Regenerative Inverter Panel “YASKAWA” 300kW , 590A : 2 Sets
-400V AC Motor for Batch Centrifugal Machine 250kW, 6 Pole
-Vertical Loading and Installation work
-Test & Commissioning at Site
-As-Built Drawing
-Protection Relay Replacement for SEL-700G at Site
-Programming Relay for V,F adjust at Front Panel with Auto Sync. Command.
-Protection Relay Setting for Co-Ordination Curve
-Test & Commissioning at Site
-Customer’s Training at Site
-Protection Relay Replacement for SEL-849 at Site
-Modification Cintrol Plate with the same Dimension with Existing.
-Protection Relay Setting for Co-Ordination Curve
-PLC Programming for Data Communication send to Center Control
-Test & Commissioning at Site
-Customer’s Training at Site
We are the engineering team who have many experience in electrical system, power generation, machine control and energy saving . And we intend to give our experience and knowledge to industry factory.